electrical - Should all Federal Pacific panels be replaced? - Home ...
2015年3月20日 · In the case of FPE subpanels, the main breaker panel should be examined -- if it is FPE as well, then go back to step 1 and examine the main panel. If the main panel is not a FPE Stab-Lok type -- the feeder breaker in the main panel will provide limited protection against gross faults and jammed breakers until the subpanel can be replaced -- so ...
Do I really need to replace a Federal Pacific Electrical panel?
2023年5月24日 · If the new AC needs a new circuit, there is no way for them to do that responsibly in an FPE panel. The old two-pole breakers are defective and the “new” Connecticut Electric aren’t any better. It would be irresponsible to add any breaker to an FPE panel, period. The panel must go. –
subpanel - Federal Pacific 200a main panel problem with oversized …
2019年8月27日 · There is a 200a FPE breaker box (yes, I am aware of all the problems). It is not in the homeowners budget to replace at this time. He has 2 issues: His panel is full; His electric furnace is an older 100a furnace. The 100a breaker in the panel is a double pole but it also over crowds the adjoining spot on the right rail.
FPE 24 Breaker Panel Swap - Home Improvement Stack Exchange
2021年10月31日 · The existing location is in my hobby room and the panel is on the wall in a suitable location meeting all the requirements in NEC 110.26. There isn't any need for a much larger panel as this is a sub panel inside the house only serving lights, outlets etc.. all the heavy hitters are in the main service panel on the exterior of the house.
electrical - Should I proactively replace my Federal Pacific service ...
2020年4月29日 · The label on the second one says FPE model R130, as the service disconnect for a 25A A/C compressor. There is a pair of fuses inside each pullout, one pair are Bussmann and the other pair is unreadable due to weathering. Both circuits are protected upstream by appropriately sized breakers in a GE panel.
Floating service panel ground - Home Improvement Stack Exchange
2018年2月12日 · Sub-panel in garage is max 200A, 40 breaker poles. Shutoff panel outside has a 200A main breaker and a single 20A branch circuit. Both panels are FPE Stab-Lok. I've added an image of the service entrance to illustrate where there was corrosion at the ground rod and service entrance RMC (both of which were recently disturbed).
electrical - What should I consider / know about before replacing …
2017年10月5日 · As I read your question which is better GFCI outlets or breakers. With this panel I would GFCI outlets for 2 reasons. First the reset will be in the location of the the appliance or device that caused the trip. 2nd I won't work on FPE panels except to replace them.
What information do I need to select a circuit breaker?
A FPE panel with stab-loc breakers from the 1970's is an automatic write up on my home inspections. There have been numerous advisories and warnings because of problems with this design. Primary problems stemmed from poor fitting breakers and possible corrosion issues.
electrical panel - What alternatives to Stab-Lok breakers are there ...
2019年7月10日 · I'm considering putting in a sub panel in my garage, and would like to do the right thing. The second article is weasel worded and doesn't identify the various brands, but by implication all of the Stab-Lok type circuit breakers are flawed.
electrical - Federal pacific breaker panel problems - Home …
2019年11月1日 · Is it a stablock FPE panel? Stablocks have bus’s issues and the breakers are notorious for not tripping. The only thing I will do to a stablock panel is replace it. Federal pacific panels have a high likelihood of causing a fire. –