![](/rp/kFAqShRrnkQMbH6NYLBYoJ3lq9s.png)
Pressure Temperature Charts Vapor Pressure in PSIG °F °C R-452A Liquid R-452A Vapor 55 12.8 122 107 60 15.6 133 117 65 18.3 145 128 70 21.1 157 140 75 23.9 171 152 80 26.7 185 165 85 29.4 199 179 90 32.2 215 194 95 35.0 231 209 100 37.8 248 226 105 40.6 267 243 110 43.3 286 261 115 46.1 305 281 120 48.9 326 301 125 51.7 348 322 130 54.4 371 ...
The information contained within this website is for guidance only, for further system specific advice please call A-Gas directly.
R-452A XP44 Refrigerant PT Chart
2020年7月11日 · R-452A closely matches the performance and energy efficiency of R-404A. You’ll also find that the compressor discharge temperature nearly matches when compared to R-404A/R-507 systems in both low and medium temperature applications.
R452A Refrigerant: Properties, Pros, Cons, Uses
2023年8月3日 · R-452A Pressure Chart. When diagnosing an air conditioner or a refrigerator, a technician will first want to look at a pressure-temperature chart (also known as a PT Chart). The document offers vital information on the pressure of a refrigerant at various temperature points.
R452A (XP44) Pressure Temperature Chart R452A (XP44) Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.28 -0.73 -10.59 0.22 -0.79 -11.46-68 0.32 -0.69 -10.01 0.25 -0.76 -11.02-66 0.36 -0.65 -9.43 0.29 -0.72 -10.44-64 0.40 -0.61 -8.85 0.33 -0.68 -9.86-62 0.45 -0.56 -8.12 0.37 ...
• PRESSURE€TEMP CHART † National [ PHYSICAL PROPERTIES OF REFRIGERANTS • R-452A Environmental Classification Molecular Weight Boiling Point (1atm, ˚F) Critical Pressure (psia) Critical Temperature (˚F) Critical Density (lb./ftˆ3) Liquid Density (70˚F, lb./ftˆ3) Vapor Density (bp.lb./ftˆ3)
R-452A saturated pressures are marginally lower than refrigerant R-404A; R-448A/R-449A pressures are slightly lower than R-404A. Compressor standards use dew point temperatures because they allow for a clear correlation between pressures and temperatures.
Pressure/Temperature Chart - Johnstone Supply
Johnstone Supply is a leading wholesale distributor for HVACR equipment, parts and supplies available and in-stock at local branches.
Solstice 452A has a moderate temperature glide between about 3 °K and 4 °K, depending upon pressure. When dealing with blends, pressure-temperature tables are presented with two pressures listed for each temperature: the dew pressure and the bubble pressure. The dew pressure is used for determining the system
Refrigerant Pressure Readings - InspectAPedia
Refrigerant Pressure / Temperature Chart & Table Downloads. Here is a list of pages where you can download free refrigerant pressure/temperature charts, provided courtesy of various HVACR manufacturers that we cite.